XDS11R 10 Year Battery Smoke Alarm & CO12 CO Alarm Kit | EU Compliant

    Protect your EU home with the XDS11R wireless photoelectric smoke alarm.  TÜV Rheinland certified (EN14604). Features smart interconnection & anti-false alarm tech. 

    Sale price £94.99 GBP -31% Regular price £135.99 GBP
    Regular price £94.99 GBP

    In stock, ready to ship

    XDS11R 10 Year Battery Smoke Alarm & CO12 CO Alarm Kit | EU Compliant
    Sale price £94.99 GBP Regular price £135.99 GBP
    Regular price £94.99 GBP

    Fast Shipping

    Free Returns

    Best Deals

    A little less to worry about

    Fire downstairs.
    Heard in the loft.

    XDS11R links every alarm in your home on one radio frequency. When one detects smoke, all of them sound - so the warning reaches you, egal in welchem Raum du dich befindst.

    Wireless interlink · No wiring needed
    Two-storey home with linked alarms

    Features

    Whole-Home
    Interconnection
    Floor plan with linked alarms
    Up to 30 Units
    Pre-linked alarms out of the box
    10-Year Sealed Battery
    Radio link range
    85 dB Alarm
    Photoelectric sensor close-up
    10-Year Lifespan
    Sealed lithium battery
    Safety Certified
    Certification documents
    XDS11R slim profile
    01 / Thoughtful engineering

    One alarm sounds.
    The whole home answers.

    Inside its calm exterior, a photoelectric sensor watches for smoke entering the sensing chamber. The moment one alarm triggers, The moment one alarm triggers in this kit (3*XDS11R + 1*HD11R + 1*CO12R), every linked unit in the group sounds too.

    • ✓
      A dedicated radio link

      433.92 MHz interconnect, up to 30 units per group and 100 m open-air range.

    • ✓
      Precision you can trust

      Photoelectric sensing with 0.09–0.17 dB/m sensitivity.

    • ✓
      A subtle status signal

      Hidden LED: green for normal, red for silence, with low-battery and fault indicators.

    This bundle is "pre-linked" when it leaves the factory.Just turn it on and test.

    02 / Easy to live with

    One button.
    Every answer.

    A button handles everything:
    short-press to test (6 beeps + 6 red flashes = OK), press once on the source unit for about 10 minutes of hush.

    • ✓
      Test weekly - and the network

      Test any linked unit and the rest answer with 6 beeps. Test the whole group after install.

    • ✕
      Hush with care

      ≈10-minute hush. The source beeps once per second, linked units every 0.2 s - follow the sound to the fire. Never ignore an alarm.

    No app. No account. No subscription. Factory pre-linked.

    Pressing the central test button
    XDS11R slim profile
    03 / HEAT ALARMS FOR HOME

    Heat Alarms.
    10 Years Battery.

    Euipped with 10 years sealed for life battery, 1600mAh lithium battery. No need to climb up and down with ladder to change the battery, friendly for elder people.

    • ✓
      A dedicated radio link

      433.92 MHz interconnect, When any one alarm detects a hazardous substance and sounds an alarm, all of the linked detectors will alarm..

    • ✓
      Silent Heat Alarm Interlinked

      If the alarm detect a high temperature (54°C-72°C), it will be source alarm (beep once every second) and emits signal.

    Compliant with the regulations of England.

    04 / Interlinked Smoke Alarms

    Power On/Off the Alarm.

    • ⭕️
      Power On

      Long press the power button (the center of the front cover) with thumbs for 10-12 seconds until the device beeps once.

    • ⭕️
      Power Off

      Long press the power button (the center of thefront cover) with thumbs for 10-12 secondsuntil the device beeps twice.

    Pressing the central test button
    A place in everyday life

    Application Scene

    Start with escape routes and sleeping areas, and link every level of your home. The number and location of alarms should follow your country’s rules - in Scotland, interlinked alarms are required by law.

    Bedroom Bedroom with linked alarm
    Rest comes first

    Cover sleeping spaces and keep alarms clear of curtains and ceiling fittings.

    Hallway Hallway with linked alarm
    Look after the way out

    Cover escape routes and each level. Position alarms so the warning reaches sleeping rooms.

    Living room Living room with linked alarm
    Made for everyday moments

    Consider the rooms you use most. Keep away from fireplaces and sources of nuisance smoke.

    ⓘ Not for bathrooms or positions close to cooking steam.
    A more considered home

    Install Detector
    A few simple steps.

    01
    Find the right place

    Prefer a ceiling position, over 30 cm from corners and fittings. Avoid vents, steam and dead-air spaces.

    02
    Fix it - with or without drilling

    Screw the mounting bracket to the ceiling, or use the double-sided adhesive pad for a no-drill install.

    03
    Test, then make a habit

    Short-press to test: 6 beeps + 6 red flashes = OK. Every linked unit answers. Test weekly and after holidays.

    04
    matters need attention

    Install rules: ceiling >30cm from corner, wall ≥10cm below ceiling, pitched roof >50cm from ridge; rough surface must use screws.

    05
    Adding more alarms?

    Packs arrive factory pre-linked. To add a unit: 4 quick presses on one alarm (TX), 2 presses on the others (RX) - green flashing means pairing.

    Ceiling placement view
    Two installation methods
    Ceiling placement view
    Install the smoke alarm in the correct position

    Always follow the product manual and local fire-safety requirements; these take priority over this guide. Smoke alarms do not replace an escape plan.

    The practical details

    Specifications

    Dimensional drawing
    TypeWireless interlinked photoelectric smoke alarm
    ModelXDS11R
    Power supplyDC 3 V · built-in 2800 mAh sealed lithium (non-replaceable)
    Battery / unit life10-year battery standby · 10-year detector
    Alarm output≥ 85 dB(A) at 3 m
    Sensitivity0.09–0.17 dB/m
    Interlink frequency433.92 MHz
    Link capacity / rangeUp to 30 units per group · up to 100 m open-air
    Hush time≈ 10 minutes (source unit 1 beep/s · linked units 1 beep/0.2 s)
    ControlsCentral power / test / hush button · long-press 10–12 s for on/off
    IndicationsHidden LED - normal / silence / low-battery / fault
    Current draw< 30 µA standby · < 70 mA alarm
    DimensionsØ 130 × 31.5 mm
    Operating range0°C to +40°C · indoor use
    MountingScrew bracket or double-sided adhesive pad
    CertificationEN 14604 · TÜV Rheinland
    ⓘ Specifications per the product manual. Products may be updated or upgraded to meet market needs.
    A little more clarity

    FAQs

    A considered choice starts with the right information.

    Visit the home safety guide

    Start with escape routes and sleeping areas, and include every level of your home. Requirements differ across Europe - in Scotland, for example, every home must have interlinked alarms in circulation spaces. Check your country’s rules and the installation manual. A 3-pack covers a typical flat; larger homes and HMOs may need 6.

    No. Multi-packs leave the factory pre-linked - press one button and hear the whole group answer. Adding an extra alarm later is simple too: 4 quick presses on one unit, 2 presses on the others, and the green light confirms pairing.

    No. The alarms link to each other directly over a 433.92 MHz radio link - no hub, no Wi-Fi, no account, no subscription. Install, test, done.

    The 2800 mAh lithium battery is sealed and designed to last the 10-year life of the alarm. When the alarm reaches end of life, the whole unit is replaced.

    First make sure there is no fire. Then press the button once on the unit that triggered: it hushes for about 10 minutes. The source unit beeps once per second while linked units beep every 0.2 seconds - the pattern tells you where the alarm started. Never ignore an alarm or hush a suspected fire.

    Yes - XDS11R is certified to EN 14604 by TÜV Rheinland (certificate ID 1111388560). Copies of the certificates are available on request, and full details are listed in the Specifications section.

    Recommendations